test STATIONS
Our Products
ORVM Cable Durability Tester
This ORVM Cable Durability Tester is a Testing Equipment Manufactured by K-PAS tests the Durability of the Mirror by Moving the Mirror in the applied directions continuously. The current testing will be used to test the MM5 Model.
The Maximum number of Mirrors which can be tested simultaneously is 6 Mirrors.
Our Actuator Manual Durability Tester uses the Latest Allen Bradley PLC and its NI LABVIEW Software so as to get fast and accurate Real Time Results for the UUT(Unit Under Test).
The Continuous Folding and Unfolding Test to be done for the Mirror for the required number of Cycles is carried out in this ORVM CABLE DURABILITY TESTER.
ORVM Manual Folding Durability Tester
This ORVM Manual Folding Durability Tester is a Testing Equipment Manufactured by K-PAS tests the Durability of the Mirror by Moving the Mirror in the applied directions continuously. The current testing will be used to test the MM5 Model.
The Maximum number of Mirrors which can be tested simultaneously is 6 Mirrors.
Our Manual Folding Durability Tester uses the Latest Allen Bradley PLC and its HMI so as to get fast and accurate Results for the UUT(Unit Under Test).
The Manual Folding Durability test are done both in Manual Mode and in Auto Mode .
There are two Servo Motors connected to the Mirror setup to run the Folding and the Unfolding Process continuously for a long time.
Actuator Manual Durability Tester
This Actuator Manual Durability Tester is a Testing Equipment Manufactured by K-PAS tests the Durability of the Mirror by Moving the Mirror in the applied directions continuously. The current testing will be used to test the MM5 Model.
The Maximum number of Mirrors which can be tested simultaneously is 16 Mirrors.
Our Actuator Manual Durability Tester uses the Latest Allen Bradley PLC and its HMI so as to get fast and accurate Results for the UUT(Unit Under Test).
The Number of Cycles Run corresponds with the Durability of the Mirror i.e., the Longer the Mirror is tested without any problems, the better the Durability.
CATHODIC DISPONDMENT TESTER – 5 PORT
- A Cathodic Disbondment Tester is used to evaluate the resistance of protective coatings (typically on steel substrates) to disbondment or delamination when subjected to cathodic protection conditions.
- It simulates the effects of cathodic polarization that occur in real-world environments such as pipelines, tanks.

- Make : K-PAS
- Model : KM-616
- Input : 230V AC 50Hz
- Output : 0 – 30V DC
- Capacity : 100mA
- High-Temperature Capability.
- Quality control of coating materials.
- Qualification of protective coatings for offshore and underground structures.
- Research and development in corrosion protection.
Electric Mirror Durability Tester
This Electric Durability Tester is a Testing Equipment Manufactured by K-PAS tests the Durability of the Mirror by Moving the Mirror in the applied directions continuously. The current testing will be used to test the MM5 Model.
The Maximum number of Mirrors which can be tested simultaneously is 6 Mirrors and more based on customer requirement Our Manual Folding Durability Tester uses the Latest Allen Bradley PLC and its HMI so as to get fast and accurate Results for the UUT(Unit Under Test).
The ELECTRIC Folding Durability test are done both in Manual Mode and in Auto Mode.
The Mirrors (UUT) are placed inside the CHAMBER which is used to HEAT and COOL the UUT’s where they are tested in different Temperatures to ensure their Durability upon use in Various Regions with Different Climatic Conditions
Cluster Testing Unit
K-PAS Cluster Testing Unit is used to check the working condition of all the functions in the cluster unit of a Motor Cycle.
| Sr. No. | Description | I/P for Cluster | I/P for Data Logger | I/P Specification |
|---|---|---|---|---|
| 1 | Brake Vacuum Pump | CAN MSG from Data logger | 12 VDC 12 VDCGround | Gnd Reference w.r.t 12 VDC ( low) |
| 2 | Engine Brush Wear | CAN message from Data Logger | 96 VDC | 96 VDC |
| 3 | High Beam | Active Low 12 VDC Ground | N/A | N/A |
| 4 | Turn Signal Indicator | Active High Signal 12 VDC + Ve | N/A | N/A |
| 5 | Economy | CAN message from Data Logger | 12 VDC | 12 VDC (High) |
| 6 | Power Charge Plug inserted | Active Low 12 VDC Ground | N/A | N/A |
| 7 | EPS | When CAN bus not connected EPS LED get continuous ON.i.e. EPS LED get ON every time as cluster get ON. | ||
| 8 | Engine temperature | CAN message from Data Logger | REFER BLINK CODE DETAILS. (After giving 8 pulses of blink code to the data logger CAN message will generate.) | |
| 9 | Auxiliary 12 V battery Low | CAN message from Data Logger | 12 VDC | 12 VDC (High) |
| 10 | DC DC convertor | CAN message from Data Logger | 12 VDC 12 VDC Ground | Gnd Reference w.r.t12 VDC ( low) |
| 11 | Park Brake | Active Low 12 VDC Ground | N/A | N/A |
| 12 | Brake Oil | Active Low 12 VDC Ground | N/A | N/A |
| 13 | Speedo meter/ Ammeter / Voltmeter | +12 VDC | N/A | N/A |
| 14 | LCD Display | +12 VDC | N/A | N/A |
| 15 | Pointer | +12 VDC | N/A | N/A |