Power Supply
Our organization is counted among the leading and trusted manufacturers and exporters of a wide range of Power Supply devices. Designed in strict conformation with industry defined norms and standards, these instruments are offered in varied technical specifications so as to meet the application based requirements of the clients in different industry verticals. Highly reliable, functionally efficient, low in maintenance and durable, the range can be availed at industry leading prices.
Our Products
AC DC Multi Power Supply
K-PAS offers a range of Linear DC Regulated Power Supplies for use in Laboratories & Industries. Output voltage and current values are displayed on a 3 digit DPM. There are various models to choose from, with output power ranging from 30- 30000 Watts. Output voltage of 0-16V, 0-32V, 0-64V, 0-100V and 0-300V,0- 500V. DC is available for single output supplies.
There is Dual output models with two independent isolated outputs. These outputs could be connected in series or parallel to double the voltage or current. All the models operate in either constant voltage ornconstant current mode and are fully protected against continuous output short circuit and overload.
The Power Supply employs the time proven series pass regulator technique. The Power Supply is forced air cooled using the best type of heat sink available and is housed in an enclosure which is sturdy, attractive and easily accessible for servicing.
This model employs constant voltage/current limiting technique, wherein the current limit comes into operation, whenever the load current is approximately 10% above the rated current.
The output is fully protected against over load, short circuit and voltage reversal due to reactive loads. The output sourced is isolated from the chassis. The output is brought out through terminal block. The output can also be monitored by a digital meter which is provided on the front panel.
| Fixed Power supply | 1) Range: ±5V/±12V/±15V/24 V/48V 2) Capacity: 0.5 Amps to 500 Amps | |
| Variable Power Supply | 1) Range: 0-16V/0-32V/0-64V 2) Capacity: 0.5 Amps to 500 Amps | |
| High Voltage Power Supply | 1) Range: 0-100V/0-300V 2) Capacity: 0.5 Amps to 60 Amps | |
| HMI INTERFACE FOR USING DESIRED VOLTAGE AND CURRENT | ||
| Metering: | 3 digit DPM | |
| HIGH PRECISION AND CONTROL THROUGH PROGRAMMING | ||
| Meter Accuracy: | ±3 counts. | |
| Constant Voltage Mode: | 1) Line: ±0.01% ±2mV for ±10% change in line output 2) Load: ±0.01% ±2mV for load change from Zero to full load 3) Ripple & Noise: 1mV rms max. 20Hz-20MHz | |
| Constant Current Mode: Regulation | 1) Line: 0. 1% for ±10% line change. 2) Load: 0.1% for change in output voltage from 0 Volts to maximum output voltage. 3) Ripple & Noise: 0.1% rms | |
| Overload Protection: | Automatic overloads and short circuit protection. | |
| Transient Response: | Within one second of set output voltage for load change from 10% to 90% | |
| Stability: | Total drift within 8 hours, after warm up. Less than 0.5% in constant voltage/current mode with constant line, load and ambient temperature conditions. | |
| Operating Temperature: | 0-50 degree | |
| INPUT VOLTAGE | 230 V AC / 1 PHASE 50HZ | |
| OUTPUT VOLTAGE AC | 24V AC, 48V AC, 110V AC | |
| OUTPUT VOLTAGE DC | 24V DC, 48V DC, 110V DC | |
| CAPACITY | 0-20AMPS | |
| PROTECTION | CONSTANT CURRENT AND HRC FUSE (INSIDE) | |
| OPERATION | CONSTANT CURRENT AND CONSTANT VOLTAGE | |
| OPERATING TEMP | 25-45°C | |
DC Regulated Power Supply
K-PAS offers a range of Linear DC Regulated Power Supplies for use in Laboratories & Industries. Output voltage and current values are displayed on a 3 digit DPM. There are various models to choose from, with output power ranging from 30- 30000 Watts. Output voltage of 0-16V, 0-32V, 0-64V, 0-100V and 0-300V,0- 500V. DC is available for single output supplies.
There is Dual output models with two independent isolated outputs. These outputs could be connected in series or parallel to double the voltage or current. All the models operate in either constant voltage ornconstant current mode and are fully protected against continuous output short circuit and overload.
The Power Supply employs the time proven series pass regulator technique. The Power Supply is forced air cooled using the best type of heat sink available and is housed in an enclosure which is sturdy, attractive and easily accessible for servicing.
This model employs constant voltage/current limiting technique, wherein the current limit comes into operation, whenever the load current is approximately 10% above the rated current.
The output is fully protected against over load, short circuit and voltage reversal due to reactive loads. The output sourced is isolated from the chassis. The output is brought out through terminal block. The output can also be monitored by a digital meter which is provided on the front panel.
| Fixed Power supply | 1) Range: ±5V/±12V/±15V/24 V/48V 2) Capacity: 0.5 Amps to 500 Amps |
| Variable Power Supply | 1) Range: 0-16V/0-32V/0-64V 2) Capacity: 0.5 Amps to 500 Amps |
| High Voltage Power Supply | 1) Range: 0-100V/0-300V 2) Capacity: 0.5 Amps to 60 Amps |
| Metering | 3 digit DPM |
| Meter Accuracy | ±3 counts. |
| Constant Voltage Mode | 1) Line: ±0.01% ±2mV for ±10% change in line output 2) Load: ±0.01% ±2mV for load change from Zero to full load 3) Ripple & Noise: 1mV rms max. 20Hz-20MHz. |
| Constant Current Mode: Regulation | 1) Line: 0. 1% for ±10% line change. 2) Load:0. 1% for change in output voltage from 0 Volts to maximum output voltage. 3) Ripple & Noise: 0.1% rms |
| Overload Protection | Automatic overloads and short circuit protection. |
| Transient Response | Within one second of set output voltage for load change from 10% to 90% |
| Stability | Total drift within 8 hours, after warm up. Less than 0.5% in constant voltage/current mode with constant line, load and ambient temperature conditions. |
| Operating Temperature | 0-50 degree |
Multi Output DC Power Supply With DC mA Source
K-PAS offers a range of Linear DC Regulated Power Supplies for use in Laboratories & Industries. Output voltage and current values are displayed on a 3 digit DPM. There are various models to choose from, with output power ranging from 30- 30000 Watts. Output voltage of 0-16V, 0-32V, 0-64V, 0-100V and 0-300V,0- 500V. DC is available for single output supplies.
There is Dual output models with two independent isolated outputs. These outputs could be connected in series or parallel to double the voltage or current. All the models operate in either constant voltage ornconstant current mode and are fully protected against continuous output short circuit and overload.
The Power Supply employs the time proven series pass regulator technique. The Power Supply is forced air cooled using the best type of heat sink available and is housed in an enclosure which is sturdy, attractive and easily accessible for servicing.
This model employs constant voltage/current limiting technique, wherein the current limit comes into operation, whenever the load current is approximately 10% above the rated current.
The output is fully protected against over load, short circuit and voltage reversal due to reactive loads. The output sourced is isolated from the chassis. The output is brought out through terminal block. The output can also be monitored by a digital meter which is provided on the front panel.
| Fixed Power supply | 1) Range: ±5V/±12V/±15V/24 V/48V 2) Capacity: 0.5 Amps to 500 Amps |
| Variable Power Supply | 1) Range: 0-16V/0-32V/0-64V 2) Capacity: 0.5 Amps to 500 Amps |
| High Voltage Power Supply | 1) Range: 0-100V/0-300V 2) Capacity: 0.5 Amps to 60 Amps |
| Metering | 3 digit DPM |
| Meter Accuracy | ±3 counts. |
| Constant Voltage Mode | 1) Line: ±0.01% ±2mV for ±10% change in line output 2) Load: ±0.01% ±2mV for load change from Zero to full load 3) Ripple & Noise: 1mV rms max. 20Hz-20MHz. |
| Constant Current Mode: Regulation | 1) Line: 0. 1% for ±10% line change. 2) Load:0. 1% for change in output voltage from 0 Volts to maximum output voltage. 3) Ripple & Noise: 0.1% rms |
| Overload Protection | Automatic overloads and short circuit protection. |
| Transient Response | Within one second of set output voltage for load change from 10% to 90% |
| Stability | Total drift within 8 hours, after warm up. Less than 0.5% in constant voltage/current mode with constant line, load and ambient temperature conditions. |
| Operating Temperature | 0-50 degree |
Programmable DC Pulse Power Supply 100A
K-PAS offers a range of Linear DC Regulated Power Supplies for use in Laboratories & Industries. Output voltage and current values are displayed on a 3 digit DPM. There are various models to choose from, with output power ranging from 30- 30000 Watts. Output voltage of 0-16V, 0-32V, 0-64V, 0-100V and 0-300V,0- 500V. DC is available for single output supplies.
There is Dual output models with two independent isolated outputs. These outputs could be connected in series or parallel to double the voltage or current. All the models operate in either constant voltage ornconstant current mode and are fully protected against continuous output short circuit and overload.
The Power Supply employs the time proven series pass regulator technique. The Power Supply is forced air cooled using the best type of heat sink available and is housed in an enclosure which is sturdy, attractive and easily accessible for servicing.
This model employs constant voltage/current limiting technique, wherein the current limit comes into operation, whenever the load current is approximately 10% above the rated current.
The output is fully protected against over load, short circuit and voltage reversal due to reactive loads. The output sourced is isolated from the chassis. The output is brought out through terminal block. The output can also be monitored by a digital meter which is provided on the front panel.
| Fixed Power supply | 1) Range: 0-100v/0-300v 2) Capacity: 0.5 Amps to 60 Amps. |
| Metering | 3 digit DPM |
| Meter Accuracy | ±3 counts. |
| Constant Voltage Mode | 1) Line: ±0.01% ±2mV for ±10% change in line output 2) Load: ±0.01% ±2mV for load change from Zero to full load 3) Ripple & Noise: 1mV rms max. 20Hz-20MHz. |
| Constant Current Mode: Regulation | 1) Line: 0. 1% for ±10% line change. 2) Load:0. 1% for change in output voltage from 0 Volts to maximum output voltage. 3) Ripple & Noise: 0.1% rms |
| Overload Protection | Automatic overloads and short circuit protection. |
| Transient Response | Within one second of set output voltage for load change from 10% to 90% |
| Stability | Total drift within 8 hours, after warm up. Less than 0.5% in constant voltage/current mode with constant line, load and ambient temperature conditions. |
| Operating Temperature | 0-50 degree |
| INPUT VOLTAGE | 415 V AC / 3 PHASE 50HZ |
| OUTPUT VOLTAGE | 0-20 V DC |
| CAPACITY | 0-100 AMPS |
| PROTECTION | CONSTANT CURRENT AND HRC FUSE (INSIDE) |
| OPERATION | CONSTANT CURRENT AND CONSTANT VOLTAGE |
| OPERATING TEMP | 25-45°C |
Programmable DC Pulse Power Supply 300A
K-PAS offers a range of Linear DC Regulated Power Supplies for use in Laboratories & Industries. Output voltage and current values are displayed on a 3 digit DPM. There are various models to choose from, with output power ranging from 30- 30000 Watts. Output voltage of 0-16V, 0-32V, 0-64V, 0-100V and 0-300V,0- 500V. DC is available for single output supplies.
There is Dual output models with two independent isolated outputs. These outputs could be connected in series or parallel to double the voltage or current. All the models operate in either constant voltage ornconstant current mode and are fully protected against continuous output short circuit and overload.
The Power Supply employs the time proven series pass regulator technique. The Power Supply is forced air cooled using the best type of heat sink available and is housed in an enclosure which is sturdy, attractive and easily accessible for servicing.
This model employs constant voltage/current limiting technique, wherein the current limit comes into operation, whenever the load current is approximately 10% above the rated current.
The output is fully protected against over load, short circuit and voltage reversal due to reactive loads. The output sourced is isolated from the chassis. The output is brought out through terminal block. The output can also be monitored by a digital meter which is provided on the front panel.
| Fixed Power supply | 1) Range: 0-100v/0-300v 2) Capacity: 0.5 Amps to 60 Amps |
| Metering | 3 digit DPM |
| Meter Accuracy | ±3 counts |
| Constant Voltage Mode | 1) Line: ±0.01% ±2mV for ±10% change in line output 2) Load: ±0.01% ±2mV for load change from Zero to full load 3) Ripple & Noise: 1mV rms max. 20Hz-20MHz |
| Constant Current Mode: Regulation | 1) Line: 0. 1% for ±10% line change. 2) Load:0. 1% for change in output voltage from 0 Volts to maximum output voltage. 3) Ripple & Noise: 0.1% rms |
| Overload Protection | Automatic overloads and short circuit protection |
| Transient Response | Within one second of set output voltage for load change from 10% to 90% |
| Stability | Total drift within 8 hours, after warm up. Less than 0.5% in constant voltage/current mode with constant line, load and ambient temperature conditions. |
| Operating Temperature | 0-50 degree |
| INPUT VOLTAGE | 415 V AC / 3 PHASE 50HZ |
| OUTPUT VOLTAGE | 0-20 V DC |
| CAPACITY | 0-300 AMPS |
| PROTECTION | CONSTANT CURRENT AND HRC FUSE (INSIDE) |
| OPERATION | CONSTANT CURRENT AND CONSTANT VOLTAGE |
| OPERATING TEMP | 25-45°C |
Programmable DC Pulse Power Supply 500A
K-PAS offers a range of Linear DC Regulated Power Supplies for use in Laboratories & Industries. Output voltage and current values are displayed on a 3 digit DPM. There are various models to choose from, with output power ranging from 30- 30000 Watts. Output voltage of 0-16V, 0-32V, 0-64V, 0-100V and 0-300V,0- 500V. DC is available for single output supplies.
There is Dual output models with two independent isolated outputs. These outputs could be connected in series or parallel to double the voltage or current. All the models operate in either constant voltage ornconstant current mode and are fully protected against continuous output short circuit and overload.
The Power Supply employs the time proven series pass regulator technique. The Power Supply is forced air cooled using the best type of heat sink available and is housed in an enclosure which is sturdy, attractive and easily accessible for servicing.
This model employs constant voltage/current limiting technique, wherein the current limit comes into operation, whenever the load current is approximately 10% above the rated current.
The output is fully protected against over load, short circuit and voltage reversal due to reactive loads. The output sourced is isolated from the chassis. The output is brought out through terminal block. The output can also be monitored by a digital meter which is provided on the front panel.
| Fixed Power supply | 1) Range: 0-100v/0-300v 2) Capacity: 0.5 Amps to 60 Amps |
| Metering | 3 digit DPM |
| Meter Accuracy | ±3 counts |
| Constant Voltage Mode | 1) Line: ±0.01% ±2mV for ±10% change in line output 2) Load: ±0.01% ±2mV for load change from Zero to full load 3) Ripple & Noise: 1mV rms max. 20Hz-20MHz |
| Constant Current Mode: Regulation | 1) Line: 0. 1% for ±10% line change. 2) Load:0. 1% for change in output voltage from 0 Volts to maximum output voltage. 3) Ripple & Noise: 0.1% rms |
| Overload Protection | Automatic overloads and short circuit protection |
| Transient Response | Within one second of set output voltage for load change from 10% to 90% |
| Stability | Total drift within 8 hours, after warm up. Less than 0.5% in constant voltage/current mode with constant line, load and ambient temperature conditions. |
| Operating Temperature | 0-50 degree |
| INPUT VOLTAGE | 415 V AC / 3 PHASE 50HZ |
| OUTPUT VOLTAGE | 0-20 V DC |
| CAPACITY | 0-300 AMPS |
| PROTECTION | CONSTANT CURRENT AND HRC FUSE (INSIDE) |
| OPERATION | CONSTANT CURRENT AND CONSTANT VOLTAGE |
| OPERATING TEMP | 25-45°C |
DC Fixed Power Supply
K-PAS offers a range of Linear DC Regulated Power Supplies for use in Laboratories & Industries. Output voltage and current values are displayed on a 3 digit DPM. There are various models to choose from, with output power ranging from 30- 30000 Watts. Output voltage of 0-16V, 0-32V, 0-64V, 0-100V and 0-300V,0- 500V. DC is available for single output supplies.
There is Dual output models with two independent isolated outputs. These outputs could be connected in series or parallel to double the voltage or current. All the models operate in either constant voltage ornconstant current mode and are fully protected against continuous output short circuit and overload.DC Regulated Power Supply (Pulse OutPut)
The Power Supply employs the time proven series pass regulator technique. The Power Supply is forced air cooled using the best type of heat sink available and is housed in an enclosure which is sturdy, attractive and easily accessible for servicing.
This model employs constant voltage/current limiting technique, wherein the current limit comes into operation, whenever the load current is approximately 10% above the rated current.
The output is fully protected against over load, short circuit and voltage reversal due to reactive loads. The output sourced is isolated from the chassis. The output is brought out through terminal block. The output can also be monitored by a digital meter which is provided on the front panel.
| Fixed Power supply | 1) Range: 0-100v/0-300v 2) Capacity: 0.5 Amps to 60 Amps |
| Metering | 3 digit DPM |
| Meter Accuracy | ±3 counts |
| Constant Voltage Mode | 1) Line: ±0.01% ±2mV for ±10% change in line output 2) Load: ±0.01% ±2mV for load change from Zero to full load 3) Ripple & Noise: 1mV rms max. 20Hz-20MHz |
| Constant Current Mode: Regulation | 1) Line: 0. 1% for ±10% line change. 2) Load:0. 1% for change in output voltage from 0 Volts to maximum output voltage. 3) Ripple & Noise: 0.1% rms |
| Overload Protection | Automatic overloads and short circuit protection |
| Transient Response | Within one second of set output voltage for load change from 10% to 90% |
| Stability | Total drift within 8 hours, after warm up. Less than 0.5% in constant voltage/current mode with constant line, load and ambient temperature conditions. |
| Operating Temperature | 0-50 degree |
| INPUT VOLTAGE | 230 V AC / 50HZ |
| OUTPUT VOLTAGE | +15 V , -15 V |
| CAPACITY | 3 A |
| PROTECTION | FUSE |
| OUTER CASE | HIGH DURABLE MS |
AC / DC POWER SUPPLY
K-PAS AC/DC power supply is an electronic device that converts Alternating Current (AC) input into Direct Current (DC) output. It is widely used in industrial, commercial, and residential applications to provide stable and regulated power to electronic systems and equipment.

- Make : K-PAS
- Model : KM-064
- Input : 230V AC
- Output : 24VDC, 24VDC, 48VDC, EXIA 24VDC, 0 – 110VDC, 0 – 230VAC
- Provides 24VDC, 48VDC, 0–110VDC, and 0–230VAC from a single input.
- Includes over-voltage, over-current, and short-circuit protection.
- Delivers consistent voltage for reliable operation of connected devices.
- Safe to use in hazardous or explosive environments (e.g., gas plants).
DC Regulated Power Supply (Pulse OutPut)
K-PAS offers a range of Linear DC Regulated Power Supplies for use in Laboratories & Industries. Output voltage and current values are displayed on a 3 digit DPM. There are various models to choose from, with output power ranging from 30- 30000 Watts. Output voltage of 0-16V, 0-32V, 0-64V, 0-100V and 0-300V,0- 500V. DC is available for single output supplies.
There is Dual output models with two independent isolated outputs. These outputs could be connected in series or parallel to double the voltage or current. All the models operate in either constant voltage ornconstant current mode and are fully protected against continuous output short circuit and overload.
The Power Supply employs the time proven series pass regulator technique. The Power Supply is forced air cooled using the best type of heat sink available and is housed in an enclosure which is sturdy, attractive and easily accessible for servicing.
This model employs constant voltage/current limiting technique, wherein the current limit comes into operation, whenever the load current is approximately 10% above the rated current.
The output is fully protected against over load, short circuit and voltage reversal due to reactive loads. The output sourced is isolated from the chassis. The output is brought out through terminal block. The output can also be monitored by a digital meter which is provided on the front panel.
| Fixed Power supply | 1) Range: 0-100v/0-300v 2) Capacity: 0.5 Amps to 60 Amps |
| Metering | 3 digit DPM |
| Meter Accuracy | ±3 counts |
| Constant Voltage Mode | 1) Line: ±0.01% ±2mV for ±10% change in line output 2) Load: ±0.01% ±2mV for load change from Zero to full load 3) Ripple & Noise: 1mV rms max. 20Hz-20MHz |
| Constant Current Mode: Regulation | 1) Line: 0. 1% for ±10% line change. 2) Load:0. 1% for change in output voltage from 0 Volts to maximum output voltage. 3) Ripple & Noise: 0.1% rms |
| Overload Protection | Automatic overloads and short circuit protection |
| Transient Response | Within one second of set output voltage for load change from 10% to 90% |
| Stability | Total drift within 8 hours, after warm up. Less than 0.5% in constant voltage/current mode with constant line, load and ambient temperature conditions. |
| Operating Temperature | 0-50 degree |
| INPUT VOLTAGE | 230 V AC / 1 PHASE 50HZ |
| OUTPUT VOLTAGE AC | 24V AC,48V AC, 110V AC |
| OUTPUT VOLTAGE DC | 24V DC, 48V DC, 110V DC |
| CAPACITY | 0-20AMPS |
| PROTECTION | CONSTANT CURRENT AND HRC FUSE (INSIDE) |
| OPERATION | CONSTANT CURRENT AND CONSTANT VOLTAGE |
| OPERATING TEMP | 25-45°C |